B0365 – Right Actuator Feedback Short To Ground
B0365 Possible Symptoms
Engine Light ON (or Service Engine Soon Warning Light)
B0365 Possible Causes
Faulty Right Actuator,Right Actuator harness is open or shorted,Right Actuator circuit poor electrical connection,Faulty Heating, Ventilation, and Air Conditioning (HVAC) Control Module
B0365 Description
The Heating, Ventilation, and Air Conditioning (HVAC) Control Module commands the air temperature actuators to move by controlling the voltage supplied on the control circuit. A signal voltage of 0 volts or a signal voltage of 5 volts rotates the air temperature actuator. A voltage of 2.5 volts stops the door. The HVAC control module determines the current position of the actuator by monitoring the voltage on the signal circuit. The feedback potentiometer is a function of the motor position. The HVAC control module controls the air temperature actuator door positions in order to maintain the selected air temperature.